Enviado em 29/07/2021 - 19:42h
Ontem por volta de umas 02:13 inicializei o teste que foi passado pelo SO que iria estar pronto umas 04:27 da manhã mas acabei desistindo por não ter notado nenhuma atualização até umas 03:47, agora estou executando novamente o SMART inicializado umas 17:30 e pouco da tarde e está assim:ubuntu@ubuntu:~$ sudo smartctl -a /dev/sda smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-42-generic] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Samsung SpinPoint M8 (AF) Device Model: ST640LM001 HN-M640MBB Serial Number: S2ULJ9DC609222 LU WWN Device Id: 5 0004cf 207c6032e Firmware Version: 2AR10002 User Capacity: 640,135,028,736 bytes [640 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5400 rpm Form Factor: 2.5 inches Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s) Local Time is: Thu Jul 29 22:12:00 2021 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 121) The previous self-test completed having the read element of the test failed. Total time to complete Offline data collection: ( 8520) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 142) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 4496 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3471 4 Start_Stop_Count 0x0032 087 087 000 Old_age Always - 13252 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 18851 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 086 086 000 Old_age Always - 14750 12 Power_Cycle_Count 0x0032 087 087 000 Old_age Always - 13194 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 576 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 064 051 000 Old_age Always - 28 (Min/Max 15/49) 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 1 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 2444 223 Load_Retry_Count 0x0032 086 086 000 Old_age Always - 14750 225 Load_Cycle_Count 0x0032 094 094 000 Old_age Always - 68532 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 275 SMART Error Log Version: 1 ATA Error Count: 2643 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 2643 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 00 08 10 e0 00 00:00:06.070 READ DMA c8 00 08 00 08 00 e0 00 00:00:06.070 READ DMA ef 10 02 00 00 00 a0 00 00:00:06.070 SET FEATURES [Enable SATA feature] 27 00 00 00 00 00 e0 00 00:00:06.070 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 a0 00 00:00:06.070 IDENTIFY DEVICE Error 2642 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 00 08 10 e0 00 00:00:06.068 READ DMA c8 00 08 f0 07 10 e0 00 00:00:06.068 READ DMA 25 00 08 f0 7f 85 e0 00 00:00:06.068 READ DMA EXT c8 00 08 80 07 10 e0 00 00:00:06.068 READ DMA 25 00 08 80 7f 85 e0 00 00:00:06.068 READ DMA EXT Error 2641 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 00 08 10 e0 00 00:00:06.036 READ DMA ef 10 02 00 00 00 a0 00 00:00:06.036 SET FEATURES [Enable SATA feature] 27 00 00 00 00 00 e0 00 00:00:06.036 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 a0 00 00:00:06.036 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 00:00:06.036 SET FEATURES [Set transfer mode] Error 2640 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 00 08 10 e0 00 00:00:06.034 READ DMA 25 00 08 f0 7f 85 e0 00 00:00:06.034 READ DMA EXT 25 00 08 80 7f 85 e0 00 00:00:06.034 READ DMA EXT c8 00 20 08 00 00 e0 00 00:00:06.034 READ DMA c8 00 08 00 00 00 e0 00 00:00:06.034 READ DMA Error 2639 occurred at disk power-on lifetime: 18850 hours (785 days + 10 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 00 08 10 e0 Error: UNC 8 sectors at LBA = 0x00100800 = 1050624 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 00 08 10 e0 00 00:00:06.033 READ DMA ef 10 02 00 00 00 a0 00 00:00:06.033 SET FEATURES [Enable SATA feature] 27 00 00 00 00 00 e0 00 00:00:06.033 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3] ec 00 00 00 00 00 a0 00 00:00:06.033 IDENTIFY DEVICE ef 03 46 00 00 00 a0 00 00:00:06.033 SET FEATURES [Set transfer mode] SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed: read failure 90% 18850 1050624 # 2 Extended offline Completed: read failure 90% 18850 1050624 # 3 Extended offline Completed: read failure 90% 18850 1050624 # 4 Extended offline Completed: read failure 90% 18846 1050624 # 5 Extended offline Completed: read failure 90% 18846 1050624 # 6 Extended offline Completed: read failure 90% 18844 1050624 # 7 Extended offline Completed: read failure 90% 18844 1050624 # 8 Extended offline Completed: read failure 90% 18844 1050624 SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed_read_failure [90% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
Test will complete after Thu Jul 29 23:04:27 2021 UTCmas notei que esse (1 0 0 Completed_read_failure [90% left] (0-65535)) não está saindo mais dessa quantia desde então até mesmo quando executei o teste ontem, isto é normal constar? o que só mudou foi quando executei este teste várias vezes após ter interrompido algumas vezes quando dei o comando: sudo smartctl -l selftest /dev/sda ... Como saber pelo terminal o término do teste? Hoje também ia instalar por cima da minha partição /dev/sda atual novamente uma formatação original de fábrica daí apareceu uma tela que até consta que a partição ainda mantém a mesma capacidade de tamanho e uso, seria uma boa idéia criar outra partição junto com essa corrompida para tentar resgatar os dados?
ubuntu@ubuntu:~$ sudo smartctl -l selftest /dev/sda smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.0-42-generic] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF READ SMART DATA SECTION === SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed: read failure 90% 18850 1050624 # 2 Extended offline Completed: read failure 90% 18850 1050624 # 3 Extended offline Completed: read failure 90% 18850 1050624 # 4 Extended offline Completed: read failure 90% 18846 1050624 # 5 Extended offline Completed: read failure 90% 18846 1050624 # 6 Extended offline Completed: read failure 90% 18844 1050624 # 7 Extended offline Completed: read failure 90% 18844 1050624 # 8 Extended offline Completed: read failure 90% 18844 1050624
Enviado em 29/07/2021 - 21:24h
Enviado em 29/07/2021 - 22:01h
Enviado em 29/07/2021 - 22:10h
Enviado em 30/07/2021 - 00:26h
Eis o resultado do primeiro testeubuntu@ubuntu:~$ sudo badblocks -sv -c 1024 /dev/sda Checking blocks 0 to 625131863 Checking for bad blocks (read-only test): 525312% done, 0:10 elapsed. (0/0/0 errors) 525313% done, 0:12 elapsed. (1/0/0 errors) 525314% done, 0:14 elapsed. (2/0/0 errors) 525315% done, 0:16 elapsed. (3/0/0 errors) done Pass completed, 4 bad blocks found. (4/0/0 errors)
Enviado em 30/07/2021 - 16:48h
Ficou o registro de 5 ou 6 erros do tipo abaixo na inicialização do disco:Programa IRPF - Guia de Instalação e Resolução de alguns Problemas
Criando uma Infraestrutura para uma micro Empresa
Criar entrada (menuentry) ISO no Grub
Como gerar qualquer emoji ou símbolo unicode a partir do seu teclado
Instalando o Pi-Hole versão v5.18.4 depois do lançamento da versão v6.0
Instalar o VIM 9.1 no Debian 12
Como saber o range de um IP público?
Muitas dificuldades ao instalar distro Linux em Notebook Sony Vaio PCG-6131L (VPCEA24FM)
Liberação de alguns links no squid (13)
impressora de rede via dominio - gpo (2)